Specifications
|
| |
Absolute Min. /Max. Supply Voltage:
8.0 / 78.0 VDC
Nominal
Battery Voltage:
12V / 6 Cell Battery Bank: 9 to 16 VDC
24V / 12 Cell Battery Bank: 18 to 32 VDC
48V / 24 Cell Battery Bank: 36 to 64 VDC
Typ.
Current Consumption:
@12.8V: @25.6V:
@51.2V:
Fan Off: 5 mA
3 mA
2 mA
Fan On: 220 mA 120
mA 60 mA
Default
Fan Turn-On / Turn-Off Voltage:
2.33 / 2.30 Volts Per Cell +/- 1%
Von,
Voff Voltage Stability:
+/- 1% typ.
Von,
Voff Voltage Range:
0 to 2.65 Volts Per Cell in 1024
increments
(Von must be a higher value than Voff)
Purge
Timer Duration & Interval:
5 Minutes every 24 Hours +/- 10%
Regulated
+12VDC Output Voltage:
12.3 Volts typ. @ Vbat > 14.0VDC
Regulated +12VDC Output Max. Current:
500 mA (including current to Exhaust
Fan)
Fan
Control Terminal Max. Ratings:
20VDC, 1500 mA
(low-side MOSFET switch)
External
Alarm Terminal Max. Ratings:
20VDC, 1500 mA
(low-side MOSFET switch)
Fan
Type:
12VDC Brushless Motor
Ball Bearings
3.5" 7-Blade Impeller
Fan
Rated Airflow:
45 CFM (free-air)
Operating
Noise:
27 dBa @ 1 Meter
(with air inlet & outlet pipes
installed)
NOTES:
1. All specs tested at 72° F.
2. Specs subject to change without notice.
3. Installed airflow will be less than the free-air rating, and will
vary by application. |
|
|
|
|